With the active technology, the pavement sensor installed directly into the surface will automatically cool down its surface until freezing occurs, measuring the temperature of ice formation. By comparing the surface temperature with the freezing point temperature of the moisture, the degree of protection is known regardless of the type of chemical already applied.

  • Situation
    • Boschung
      Airport
    • Boschung
      Highway and Road
    • Boschung
      City and Municipality

Specifications

Measurements

  • Freezing point temperature

    -30… 0°C

  • Accuracy

    from -15°C to +0°C: ±0.5°C otherwise: ±1.5°C

  • Resolution

    0.1°C

Subject to technical modifications without prior notice.

  • Communication

    • Interface

      RS485

    • Protocol

      Boschung proprietary or open text protocol using ASCII codes

  • Electrical characteristics

    • Power supply

      24 to 48 VDC

    • Consumption

      < 0.5 W @ 24 VDC peak : 16 W (30m cable)

  • International standards

    • EMC compatibility
    • EN 61000-6-1

      (immunity / residential environment)

    • EN 61000-6-2

      (immunity / industrial environment)

    • EN 61000-6-2

      (immunity / industrial environment)

      • ESD: EN 61000-4-2 with ±25 kV (instead of 8 kV)
      • Burst: EN 61000-4-4 with ±4 kV (instead of 1 kV)
      • Surge: EN 6100-4-5 with ±2 kV (instead of 1 kV)
    • EN 61000-6-3

      (emission / residential environment)

    • EN 61000-6-4

      (emission / industrial environment)

    • Stand-alone casing

      • Stand-alone casing

      • Integral cable

        Standard: 30 m, longer on demand

      • Cable type

        specific: one pair 1.5 mm2 (power supply) + one pair 0.5 mm2 (RS485)

      • Cable splicing

        up to 600 m (depending on power supply)

      • RS485 extension cable (recommended)

        twisted pair, shielded, ø 0.8 mm

      • Dimensions

        ø90 mm x 42 mm

      • Weight (with standard cable)

        4.2 kg

    • Econ case

      • Econ case (road application)

      • Integral cable

        Standard: 30 m, longer on demand

      • Cable type

        specific: one pair 1.5 mm2 (power supply) + one pair 0.5 mm2 (RS485)

      • Cable splicing

        up to 600 m (depending on power supply)

      • RS485 extension cable (recommended)

        twisted pair, shielded, ø 0.53 mm

      • Dimensions

        ø135 mm x 51 mm

      • Weight (with standard cable)

        4.6 kg

    • Airport case

      • Airport case

      • Cable type

        specific: one pair 1.5 mm2 (power supply) + one pair 0.5 mm2 (RS485)

      • Cable splicing

        up to 600 m (depending on power supply)

      • RS485 extension cable (recommended)

        twisted pair, shielded, ø 0.53 mm

      • Dimensions

        330 x 154 x 43.2 mm

      • Weight (with standard cable)

        8.4 kg

    Are you looking for an active Ice Early Warning System?

    Boschung RWIS, Weather Stations, Surface Sensors, Highway
    Close

    Enquire about the IT-ARCTIS

    Receive advice about product specifications and find the right Boschung equipment for your needs.

    This field is required.
    This field is required.
    This field is required.
    This field is required.
    This field is required.
    This field is required.
    Submit